Government Mission Critical Areas
Staticworx™ ESD Carpet in Government
Mission Critical Areas
Staticworx™ supplies ESD
flooring products to United States Military facilities around
the globe, including this Flight Control Tower at an undisclosed
location in the Middle East.
A U.S. Military Air Traffic Control facility in the
Middle East was having problems with their CONTROL ACCESS
UNITS (CAUs). Each of the three CAUs in the tower
controls a specific position vital to airfield management
and safety. Using the CAUs, the controllers maintain constant
contact with all individuals and vehicles on the airfield,
on the ground and in the air. Loss of contact could lead
to problems ranging from holdups in traffic to airfield
collision or aircraft crash. These units (CAUs) are costly
and in short supply, with requisitions for parts taking
upwards of 45 to 60 days. The facility was replacing
two units a month.

U.S. Military personnel applying
adhesive for Staticworx™ ESD Carpet installation |
An investigation revealed
that static electricity was causing unit failure in
the control tower. When the Air Traffic Controllers
(ATCs) walked across the tower floor, a static charge
built up on their bodies (walking body voltage). When
the controllers touched the control heads, that static
charge was transferred to the units, damaging the electronic
components inside the CAUs and causing unit failure.
To solve the problem, ground plates were installed and
the controllers were required to wear wrist straps.
However, the wrist straps inhibited mobility, compromising
the controllers’ performance. A permanent, more
user-friendly solution was needed.
Staticworx™ static control carpet
proved to be the solution. Conductive fibers, woven
into each yarn bundle of the Staticworx™ carpet, create
an infinite number of contact points, providing a fast
path to ground to quickly and safely remove static charges.
This exclusive Fibrelink construction provides
uncompromising performance in any environment, regardless
of temperature or humidity. Also, no wrist or heel straps
are required, allowing the controllers unfettered mobility
in the tower. Since installing Staticworx™ ESD carpet
in the control tower, not a single CAU has needed replacement.
[Government Applications] [Mission
Critical Applications]
|